SAFETY RELAY PHOENIX PSR-SCP-42-230UC/URM4/4NO/2NC – 2702924
- Technical information
- Download catalog
Maximum power dissipation for nominal condition | 16.1 W (At IL² = 72 A², PTotal max = 1.7 W + 14.4 W) |
Nominal operating mode | 100% operating factor |
Air clearances and creepage distances between the power circuits | |
Rated insulation voltage | 250 V AC |
Rated surge voltage/insulation | |
Supply | |
Rated control circuit supply voltage US | 42 V AC/DC -15 % / +10 % |
230 V AC/DC -15 % / +10 % | |
Rated control supply current IS | typ. 35 mA (At 42 V DC) |
typ. 15 mA (@ 230 V AC) | |
Power consumption at US | 1.5 W (with DC) |
1.7 W (with AC) | |
Apparent power | max. 3.5 VA (at US) |
Inrush current | < 38 A (Δt = 50 µs at Us) |
Protective circuit | Surge protection; Suppressor diode and varistors |