SAFETY RELAY PHOENIX PSR-SCP- 24DC/TS/SDOR4/4X1 – 2986096
- Technical information
- Download catalog
Product type | Safety device |
Application | PSR-TRISAFE-M extension module |
Insulation characteristics: Air clearances and creepage distances between the power circuits | |
Overvoltage category | III |
Pollution degree | 2 |
Times | |
Response time | max. 50 ms |
Recovery time | < 10 s |
Maximum power dissipation for nominal condition | 3932 mW (up to 40°C ambient temperature, at m = 4, n = 4, Iload = 4 A, Isignal = 50 mA) |
1532 mW (up to 55°C ambient temperature, at m = 4, n = 4, Iload = 1 A, Isignal = 50 mA) | |
Nominal operating mode | 100% operating factor |
Interfaces | DIN rail TBUS for connection to the master module, supplied as standard |
Air clearances and creepage distances between the power circuits | |
Rated insulation voltage | 250 V AC |
Rated surge voltage/insulation | 4 kV / basic insulation between output contact current paths (13/14, 23/24, 33/34, 43/44); 6 kV / safe isolation, reinforced insulation between output contact current paths (13/14, 23/24, 33/34, 43/44) and the other circuits |
Supply | |
Rated control circuit supply voltage US | 18 V DC … 30 V DC (Incl. all tolerances, incl. residual ripple) |
Rated control circuit supply voltage US | 24 V DC (Electrical supply via PSR-TBUS) |
Rated control supply current IS | Electrical supply via PSR-TBUS |
74 mA (At 24 V DC, relay outputs set) | |
54 mA (At 24 V DC, relay outputs not set) | |
Protective circuit | Yes, within the scope of the operating voltage limits |
Status display | 1 x green LED, 1 x red LED |