2866491 – TRIO-PS/1AC/48DC/ 5 – BỘ NGUỒN TRIO 1PHA 5A – PHOENIX CONTACT – TIENHUNGTECH
- Technical information
- Download catalog
- Photo realistic
| Nominal input voltage range | 100 V AC … 240 V AC |
| Input voltage range | 85 V AC … 264 V AC (derating < 90 V AC: 2.5 % per Kelvin) |
| Derating | < 90 V AC (2.5 %/V) |
| Input voltage range AC | 85 V AC … 264 V AC (derating < 90 V AC: 2.5 % per Kelvin) |
| Electric strength, max. | 300 V AC |
| Voltage type of supply voltage | AC |
| Inrush current | < 15 A |
| Inrush current integral (I2t) | < 0.7 A2s |
| AC frequency range | 45 Hz … 65 Hz |
| Mains buffering time | > 15 ms (120 V AC) |
| > 16 ms (230 V AC) | |
| Current consumption | 2.5 A (120 V AC) |
| 1.3 A (230 V AC) | |
| Nominal power consumption | 282 VA |
| Protective circuit | Transient surge protection; Varistor |
| Power factor (cos phi) | 0.96 |
| Typical response time | < 1 s |
| Permissible backup fuse | B10 B16 |
| Recommended breaker for input protection | 10 A … 16 A (Characteristics B, C, D, K) |
| Discharge current to PE | < 3.5 mA |
| Efficiency | > 89 % (for 230 V AC and nominal values) |
| Output characteristic | U/I |
| Nominal output voltage | 48 V DC ±1 % |
| Setting range of the output voltage (USet) | 30 V DC … 56 V DC (> 48 V DC, constant capacity restricted) |
| Nominal output current (IN) | 5 A (-25 °C … 55 °C) |
| Derating | 55 °C … 70 °C (2.5%/K) |
| Feedback voltage resistance | 60 V DC |
| Protection against overvoltage at the output (OVP) | < 60 V DC |
| Max. capacitive load | unlimited |
| Active current limitation | Approx 5.7 A (in the event of a short-circuit) |
| Control deviation | < 1 % (change in load, static 10 % … 90 %) |
| < 2 % (change in load, dynamic 10 % … 90 %) | |
| < 0.1 % (change in input voltage ±10 %) | |
| Residual ripple | < 50 mVPP |
| Output power | 240 W |
| Peak switching voltages nominal load | < 50 mVPP |
| Maximum no-load power dissipation | 7 W |
| Power loss nominal load max. | 28 W |
| Rise time | < 2 ms (UOUT (10 % … 90 %)) |
| Connection in parallel | yes, for redundancy and increased capacity |
| Connection in series | yes |
Are you in need of advice?
Tien Hung always supports 24/7