SAFETY RELAY PHOENIX PSR-CT-GWY-1DGN-IOL-PI – 1106407
- Technical information
- Download catalog
| Maximum power dissipation for nominal condition | 0.9 W (when IO-Link is inactive) |
| Nominal operating mode | 100% operating factor |
| Air clearances and creepage distances between the power circuits | |
| Rated insulation voltage | 30 V |
| Supply | |
| Designation | L+/L- |
| Nominal voltage for I/O supply | 24 V DC -20 % / +25 % (Provided via the IO-Link interface of the IO-Link master.) |
| Current consumption | typ. 14 mA (if the switch chain is active, normal operation) |
| typ. 13 mA (if the switch chain is inactive) | |
| Protective circuit | Serial protection against polarity reversal |
| Suppressor diode | |
| Supply | |
| Designation | 24V/GND |
| Inrush current | typ. 3.1 A (Δt < 1.2 ms) |
| Filter time | 1 ms (in the event of voltage dips) |
| Power consumption at UD | typ. 0.1 W (IO-Link active, normal operation) |
| typ. 0.85 W (IO-Link inactive) | |
| Protective circuit | Serial protection against polarity reversal |
| Suppressor diode | |