Product portfolio
Trademark
  • WEIDMULLER
  • RITTAL
  • CMP
  • JJ-LAPP
  • MURR ELEKTRONIK
  • TIEN HUNG LED
  • BALLUFF
  • MITSUBISHI ELECTRIC
  • PHOENIX CONTACT
  • OMRON
  • PEPPERL + FUCHS
  • SCHNEIDER
  • SIEMENS
  • SIGEA
  • BIHL+WIEDEMANN
  • KROHNE
  • LEINE LINDE
  • IFM
  • SCHMERSAL
  • ELMEX
  • TELTONIKA
  • BECKHOFF
  • WAGO
  • SCHNEIDER
  • ABB
  • ALLEN BRADLEY
View more
POWER SUPPLY
  • 1 PHASE
  • 3 PHASE
View more
TERMINAL BLOCK
  • SCREW CONNECTION
  • PUSH-IN CONNECTION
  • SPRING CONNECTION
View more
RELAYS
  • PLC RELAY
  • GLASS RELAY
  • SAFETY RELAY
View more
ETHERNET SWITCH
  • 4 GATES
  • 5 GATES
  • 7 GATES
  • 8 GATES
  • 14 GATES
View more
CURRENT TRANSFORMERS
View more
ÖLFLEX® - CABLES
  • GENERAL APPLICATIONS
  • SPECIAL APPLICATIONS
  • APPLICATIONS FOR CONSTRUCTION
  • APPLICATIONS FOR RENEWAL ENERGY
  • CABIN CONTROL APPLICATION
  • HARD ENVIRONMENT
  • ROLLING STOCK
View more

RELAY MODULE KFD2-RSH-1.2E.L3-Y1 – PEPPERL+FUCHS

Product code:
KFD2-RSH-1.2E.L3-Y1
Item status:
In stock
Origin:
Germany
Product Description

Pepperl+Fuchs importer and distributor

Please refer to the detailed catalog through the following link (sourced from: https://www.pepperl-fuchs.com)
RELAY MODULE KFD2-RSH-1.2E.L3-Y1 – PEPPERL+FUCHS

Share products
  • Technical information
  • Download catalog

1-channel signal conditioner 24 V DC supply Logic input 20.5 V DC … 26.4 V DC Recommended connectable voltage 50 V AC … 230 V AC, 60 V DC … 110 V DC Relay contact output for energized to safe function Line fault transparency (LFT) Diagnostic function Up to SIL 3 acc. to IEC/EN 61508 Input Connection side control side Connection terminals 7+, 8- Pulse/Pause ratio min. 150 ms / min. 150 ms with disabled internal fault detection min. 1 s / min. 1 s with enabled internal fault detection Test pulse length max. 2 ms from DO card Signal level 0-signal: -5 … 5 V DC 1-signal: 20.5 … 26.4 V DC Rated current 0-signal: typ. 1.6 mA at 1.5 V DC; typ. 8 mA at 3 V DC (maximum leakage current DO card) 1-signal: ≥ 36 mA (minimum load current DO card) Inrush current < 200 mA after 100 µs Output Connection side field side Connection external voltage : terminals 5+/L, 2-/N load : terminals 6, 3 Connectable voltage 50 … 230 V AC 60 … 110 V DC Power dissipation < 3.3 W at 5 A , see derating curves Contact loading 253 V AC/5 A/cos φ 0.7; 30 V DC/5 A resistive load , see derating curves Minimum switch current 10 mA Mechanical life 5 x 106 switching cycles Line fault detection low voltage < 35 V AC undercurrent: 10 mA AC; overcurrent: 5.5 A AC (relay energized) breakage: 48 kΩ; short-circuit: 29 Ω (load, relay de-energized)

Are you in need of advice?

Tien Hung always supports 24/7

Mr Vo Anh Vu General Manager 0908 878 633
Mr Truong Thai Di General Manager 0933 744 776
Mr Huynh Ngoc Hoang Director 0979 652 190
Mr Nguyen Minh Hoang Sales Engineer 0908 210 127
Ms Nguyen Ngoc Duyen Sales Admin 0933 327 183